Set Tolerance Curve
• ByselectingNoneintheSmoothingoption
boxyoucanlinearlylinkthedenedreference
values. When you choose the options Yes or
More, however, help values will be created to
obtain as round a curve as possible.
There are two ways of creating reference values:
• Addadditionallinestothelistofreference
values; enter the position (At) and both limiting
values (Lower and Upper) in the table. Then,
the reference values will be shown in the chart.
• Movethecursorintothechartanddragitfrom
the upper to the lower limiting value while
pressing the mouse button. When releasing the
button, the program will insert a new reference
value.
In the chart, the reference values are indicated as
small circles; these circles can be moved with the
mouse in order to move the reference value.